Function 1: System parameters IVX X-Class Administrator’s Manual
B.2
Function 142: Automatic time setting
1: Synchronize with Caller ID
1
This function, when enabled, synchronizes the real-time clock with Caller ID (CID) messaging:
call processing compares the time of a CID message to the system real-time clock and, if the
difference is more than two minutes, resets the real-time clock to match the time (hours and
minutes) of the CID message. The system will analyze each such message (or — if it receives
more than four calls with CID information within a one-minute period — as is needed). Select
ENABLE or DISABLE by pressing a scroll key (either
or
). Choosing ENABLE will allow
the CID data to update the time and date.
Default: Disabled.
Note: If you’re using Esi-Link, consult your ESI Reseller for additional information.
2: Adjust for Daylight Saving Time
This function, when enabled, causes the real-time clock to adjust itself automatically for Daylight
Saving Time (DST). Select AUTO or DISABLE for DST by pressing a scroll key (either
or
).
Choosing DISABLE is best for those areas that don’t observe DST.
Default: Disabled.
Note: If this function is enabled and it causes an automatic time change, the system won’t update
the real-time clock from either Caller ID messages (Function 1421, above) or Esi-Link time
synchronization for 25 hours before and 25 hours after the time change is due to be effective
(i.e., 2:00 AM Sunday).
Function 143: Clock adjustment
This function lets the Installer or Administrator have the system automatically compensate for a
clock that’s running too fast or too slow. The clock adjustment speeds up or slows down the
clock over a 30-day period by the amount selected. If the system clock is running slow, select a
positive value. If the clock is running fast, select a negative value.
Range: -2 to +5.5 minutes. Default: 0.
Example: If the clock is running two minutes fast over a month, select -2 (minus two minutes)..