ESI-50L Hardware Installation Manual Hardware installation
F.1
Hardware installation
Site location
As with most electronic equipment, the environmental considerations for this site need to observe good common
sense. Provide a dry, clean, and accessible area.
Locate space in the telephone equipment room, which will provide easy connection to the 66 blocks and 110 VAC
power. The location should be no further than 1,000 feet from the farthest station.
Ambient room temperature must be 40
0
–80
0
(F.), and relative humidity no higher than 90%.
Notes: Do not place the equipment or run station cabling near high voltage electrical equipment or electrical lines
susceptible to high voltage surges from air conditioner compressors, etc.
Do not mount the equipment in a place that receives direct sunlight.
The system and supporting components should be mounted to a half-inch (or thicker) plywood backboard. Here is
the layout of a typical Base Cabinet installation.
ESI-50 Base Cabinet typical installation