ESI-50L Hardware Installation Manual Overview
A.1
Overview
Cabinet components
The ESI-50L’s cabinet components
1
consist of the standard Base Cabinet and an optional Expansion Cabinet.
The ESI-50L can accept one Expansion Cabinet.
Base Cabinet
The ESI-50L Base Cabinet is designed for easy installation and component access. The Base Cabinet,
which measures 8.5
W 11 H 3 D, houses a main board with a built-in 482 card, as well as the Memory
Module, Network Services Processor (NSP), one multi-purpose serial port, an MOH connector, an additional
port card slot (see “Port card,” below), and an external wall-mounted power supply.
Expansion Cabinet
The ESI-50L’s optional Expansion Cabinet contains two port card slots, providing a total system capacity of
three port cards (in addition to the built-in 482 card).
Main board
The ESI-50L main board combines leading-edge hardware components — including a Motorola
®
ColdFire
®
processor and DSP structure — along with proprietary operating system software. The board provides: system
control of the Memory Module and port cards; a standard RS-232C DB9 serial port; a built-in modem for remote
access; an external paging-device interface; MOH interface; and an NSP, which provides remote access via
TCP/IP and supports certain optional ESI PC software applications.
Memory Module
The Memory Module — a CompactFlash
®
with proprietary formatting — contains all system programming
and configuration data, and pre-loaded voice prompts. The Memory Module provides voice storage at 64 kilobits
per second — the industry's highest-quality sampling rate — and has a voice storage capacity of 15 hours.
Power supply
The ESI-50L’s 3-amp, 24 VAC power supply is included at purchase.
Port card options
Whether built-in or external, each 482 card
2
provides circuits to connect up to four loop-start CO lines, eight
Digital Feature Phones, and two analog station ports. The CO line ports support standard CO and Centrex loop-
start lines; ground-start CO lines are not supported. Only one analog device can be connected to each analog
station port. This card uses 10 station ports and four CO ports when installed.
Notes: The main board comes in a four-line, eight-digital station, two-analog port configuration. You can add three
482 port cards on an ESI-50L. Therefore, the system can have the following configurations.
4 8 2: Base Cabinet (main board only)
8 16 4: Base Cabinet with one additional 482 port card.
12 24 6: Base Cabinet with one additional 482 port card and an Expansion Cabinet
with one 482 port card.
— 16 32 8: Base Cabinet with one additional 482 port card and an Expansion Cabinet with
two 482 port cards.
1
Memory Modules and port cards are packed separately and are mounted in each system’s cabinet during installation.
2
The external 482 card also is used by the ESI-50L, the ESI C-Plus, and IVX S-Class Generation II systems.
Page view 2
1 2 3 4 5 6 7 8 ... 26 27

Comments to this Manuals

No comments