Function 3: Extension programming IVX C-Class Installation Manual
F.2
7. Extension page zone assignment — (The all-page zone, 0, is the only page zone available
on IVX C-Class with Integrated Answering Machine.)
The overhead paging port (extension 199) can be paged along with other extensions in a
zone by including the desired page zone for extension 199.
All digital phone extensions are included in (and cannot be removed from) the all-page zone.
Analog extensions cannot be included in page zones.
8. Operator translation — Extension 0 (Operator) programming requires:
• Programming call forwarding for day and night mode
• Entering the extension number to which calls are to be directed when someone dials 0.
Default: 100.
Analog ports
The last 2 station ports can be programmed only as follows:
1. 2. 3. 4.
Ext. Type Name CO
0
Operator
100
DIGITAL Jane 9
101
DIGITAL Roger 9
102
DIGITAL Sally 9,8
112 PHONE / FAX / MODEM / RINGER / DOOR PHONE / FAX / MODEM / RINGER / DOOR 9
113 PHONE / FAX / MODEM / RINGER / DOOR PHONE / FAX / MODEM / RINGER / DOOR 9
Here are the steps for programming analog ports:
1. Phone number — Analog port extension numbers must be X112 or X113.
2. Type — If ANALOG PORT is selected, then the ports can further be defined as follows; the
words in parentheses (EXAMPLE) indicate what the display will show in each case:
Phone (EXT) — Designed to provide for standard 2500 type phones. See the IVX C-Class
User’s Guide for complete description of the capabilities.
Common ringer (RINGER) — Connected via a tip and ring pair; will apply ring voltage
whenever a line rings in night mode or when a call is directed to it (transfer, call forwarding,
CO ring, etc.).
Fax (FAX) — If the Integrated Answering Machine answers and detects a fax tone, it will
automatically forward the tone to the analog port programmed as FAX.
Modem (MODEM) — Incoming calls for a modem can be manually transferred to the
modem extension; also, the modem can automatically generate outbound calls. Maximum
connect speed through the PBX is 9600 bps.
Door phone (DOOR) — A telephone connected to this port will automatically dial the
programmed ring down extension number whenever the set is taken off-hook.