ROMES Server Setup
1SP52_1E.doc Rohde & Schwarz Voice Quality Measurements with R&S ROMES
6 ROMES Server Setup
Preparation for an answering machine
With an digital answering machine you will only be able to measure the downlink.
Configure the answering machine so that it will accept the incoming call immediately.
Prepare the wave file: With an audio editing software such as “Audacity” the wave file
should repeat the sample file many times (60 times for example).
At the beginning of the wave file you should add a silence of at least 2500 ms. Use the
unchanged sample file on the client PC
.
Preparation for an SQA server
The ROMES Speech Quality Analyser Server allows Speech Quality Tests for the
downlink and uplink. This option offers a real end-to-end test solution.
In outgoing wave mode, the server plays sound files to a calling device. In incoming wave
mode the server measures speech quality of sound coming from a calling device using the
PESQ algorithm. The measurement results are stored in CMD files which can later be
merged into a destination CMD file by the ROMES application.