ESI U46DJ User Manual Page 11

  • Download
  • Add to my manuals
  • Print
  • Page
    / 19
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 10
ROMES Setup
1SP52_1E.doc Rohde & Schwarz Voice Quality Measurements with R&S ROMES
(3) If you are using an answering machine select “Downlink”. With an SQA server can
select “Both (Up- and Downlink)”. You have to configure reference files and pauses
to match your server configuration. (see Figure 2)
(4) Select the correct audio card for each mobile. For M-Audio and ESI U46DJ only use
the ASIO sound drivers. The ASIO drivers have to be different, to avoid sound card
driver conflicts.
If you are using an answering machine and want to use the “Initial pause” add a silent
prefix with the length of the initial pause to the edited reference file.
11.3s
8.4s
DL
UL
PESQ algorithm
Initial Pause End Pause PESQ algorithm
8.4s
Initial Pause
2.5s
9s 2.5s
Initial Pause
8.4s
Play file
End Pause
9s
11.3s
Initial Pause
9s
End Pause
Time
Figure 2 Timeline of the SQA settings above
It is recommended to adjust the “End Pause” and the “Initial Pause” so that the uplink and
the downlink do not overlay. The PESQ values could decrease.